▲The main material requirements are high-strength aluminum alloy profiles, not less than 6063,and the processing grade reaches T5 standard. The overall fully enclosed design, no sharp angle on the surface, no exposed screws, imported powder coating surface treatment;

▲The horizontal cross arm of the pendant tower has a safety bearing device, and the pendant tower has a central shaft rotating device

▲The inside of the pendant tower adopts a gas-electricity separation design to ensure the safety of use: the bottom end of the pendant box must have an oxygen drainage hole design to prevent the accumulation of oxygen in the tower and the power line caused by fire accidents.

▲ Through the static force load test, under the load state, the angular offset of the cantilever angle relative to the horizontal position is ≤ 1.5°

▲ Gas terminal All gas sockets and joints are produced by the original factory, the terminal has passed antibacterial (E. coli) detection, gas sockets are identified as different colors and different

shapes, with anti-misinsertion function, and have Standby (in-place to be connected) function, socket plug can ensure more than 20,000 times of plugging and unplugging, can be repaired with gas.

▲The power socket is AC 220V and has a separate grounding wire, the socket needs to have an equipotential grounding terminal, the grounding wire shall not be shared with the pendant tower grounding,

and communication interfaces, video interfaces, and networks can be installed as needed

★ The maximum carrying capacity of the pendant tower ≥ 680Kg

★ The pendant tower has a four-fold load-bearing factor safety load device.

1. The rotation angle of the boom (including the boom column) is not less than 340°, and the six-point damping brake system has adjustable resistance.

2. Pallet carrying weight≥ 80kg; Pallet with drawer carrying weight≥ 50kg; Drawer carrying capacity≥ 20kg.

3. The length of the middle shaft of the pendant tower ≥ 180mm, and the diameter ≥ 110mm; Wall thickness≥ 17mm;

4. Three-chamber pendant tower cross arm rotation angle ≥ 340º, length ≥ 850mm, width ≥ 190mm, height ≥ 125mm, wall thickness ≥ 10mm;

5. The length of the hanging pipe connected to the tower box can be customized according to the height of the room, the diameter is ≥ 100mm, and the wall thickness is ≥4mm;

6. The tower box rotates ≥ 340º, the height is ≥ 900mm, and it can be lifted and lowered by 250MM electrically; THE TRAPEZOIDAL BOX HAS NO ANGULAR DESIGN (LENGTH 36CM X WIDTH 21CM), WITH A STAINLESS STEEL INFUSION PUMP BRACKET ON THE LEFT AND RIGHT SIDES OF THE BOX, AND A SYRINGE PUMP FRAME WITH A FOUR-SECTION PAGODA SHAPE AND A SPIRAL FIXED STRUCTURE ON THE LOWER SECTION.

7. The center distance between the infusion pump brackets on both sides is ≥ 450mm, the length of the infusion pump bracket is ≥830mm, and the diameter of the infusion pump bracket is ≥ 25mm; Can hang ≥ 6 infusion pump syringe pump of different specifications; Equipped with 1 set of rotatable extension infusion stand, swivel arm ≥ 350mm.

8. Box tray: 2pcs, the pendant tray is an eight-cavity aluminum alloy integrated die-casting molding; The pallet fixing method adopts reinforced aluminum alloy tripod support, the tripod is ≥ 120mm long, 40mm wide ≥, ≥8mm thick, the center distance of the fixed slide rail on both sides is ≥134mm, the length of the pallet including side rail is ≥515mm, the length of the side rail is not included≥ 455mm, the width ≥ is 400mm, the thickness ≥ is 25mm, the stainless steel side rail on both sides is ≥ 350mm, the width ≥ is 10mm, the height ≥is 20mm, and the hanging net basket is optional;

9. Drawer: 1pc, inner diameter of drawer≥ 320mm, width ≥ 240mm, height ≥ 120mm, pull-out length ≥ 20mm; Drawer outer diameter size≥ length 430mm, width ≥ 300mm, height ≥ 160mm; Drawer with automatic suction design;

▲Each set is equipped with air source: oxygen * 2pcs, negative pressure suction * 2pcs, compressed air * 1pc; Optional negative pressure suction device, and oxygen inhaler (the same brand as the hanging tower, providing medical device filing certificate)

▲Each set of configuration ≥ 6 power sockets (compatible with national, American and British standards);

▲Grounding terminal *2pcs; Network interface *1pc; The configuration can be upgraded and can be flexibly selected according to user requirements.


Standard configuration:

Base *1 set、Shield *1 pc、Crossarm *1 set、Pipe*1 set、Box *1 set、Tray * 2 pcs、Drawer *1 pc、Infusion rack *1 pc、Oxygen * 2 pcs、Negative pressure attraction * 2 pcs、Compressed air *1 pc、Sockets *6 pcs、Grounding terminal * 2 pcs、Network cable interface * 1 pc、Manufacturer qualification information *1 set