Veterinary Medical Solution Supplier

Intergrated veterinary anesthesia machine WMV680I

Share:

PRODUCT DETAILS

VCV

It can be used when deep anesthe-sia, and animal completely rely on the ventilator to maintain breathing Just set the animal weight,other Parameter are calculated automatically.

PCV

Used when the animal's lungs cannot withstand too high pressure,the ventilator delivers gas to the animal according to a preset pressure.

SPONT

This mode can avoid breathing confrontation,and it can generally be used during animal recovery, or when the animal is lightly anesthetized and has spontaneous breathing.

MANUAL

In this mode, the venti lator not control and help animal breath, but only monitors the animal's breathing state through sensors and monitors breathing parameters

Intergrated veterinary anesthesia machine WMV680I

Technical Parameters

Main Unit:

Work mode: Cir

Application range: Animal weight 0.8-120kg

Oxygen flush:25L/min-75L/min

High quality aluminum trolley

CO2 absorber:

Integrated design of animal-specific integrated

bellows and absorber

Dedicated fresh gas connection to non-breath-

ing circuit

Visible inspiration and expiration valve design

to observe the breathing state easy.

Professional active pressure release valve

design, it is connected to the exhaust gas

recovery system, and provides continuous

2cmH20 negative pressure for air bag

Airway pressure real-time monitoring

Quick change soda lime canister design

Strong air tightness and reduced airway resis-

tance

Flowmeter

Animal-specific oxygen 2 tube

Flow:0-1&1-10L/min

O2 and Air

O2 flow: 0-10L/min

Air flow: 0-10L/min

Ventilator

Drive mode: Turbine and electronic control

Ventilation mode:

VCV.PCV,SPONTD(APENA),MANULAO

DEMO

Bellow:0-300ML: 0-1500ML

Waveform: pressure, flow, volume, end ex-

piratory

Loop: pressure-volume; pressure-flow,-

flow-volume

Tidal volume: machine control:3-1600ml

Manual:5-1600ml

Breathing rate:1-100bpm

I:E: 9.9:1 to 1:9.9

Inhalation time:0.1-10.0s

Inspiratory pause%:0-50%

PEEP:OFF,3-20 cmH20

Pressure support:0-60 cmH20

Pressure control:5-60 cmH20

Flow rate trigger: 0.5-20L/min

Pressure trigger:-1--20 cmH20

PSV inspiratory terminal level: 25%

Anesthesia Vaporizer:

With pressure, flow and temperature auto-

matic compensation

Concentration

range:Isoflurane:0.2-5%

Sevoflurane:0.2-8%

Halothane:0.2-5%

Flow rate range:0.2-15L/min

 

Monitor Parameter

Inspiratory/expiratory tidal volume., breathing

rate, spontaneous breathing rate, I:E ratio,

driving gas pressure, spontaneous venti-

lation volume, minute ventilation, peak/air-

way/mean airway pressure/PEEP end-tidal

pressure, inspiratory plateau pressure FIO2,

ETCO2

 

Alarm parameters

Tidal volume, minute ventilation, breathing

rate, airway pressure, peak airway pressure,

apena alarm. gas supply pressure failure

alarm, power supply alarm, pipeline detach-

ment or air leakage, low air gas pressure,

PEEP end-tidal pressure, FIO2, FiCO2

Intergrated veterinary anesthesia machine WMV680IIntergrated veterinary anesthesia machine WMV680I

Human-machine friend-ly interface, fool-like 

operation and only need set the weight!

Flow & pressure & volume waveforms, and pressure 

loop & flow loop, volume loop mon-itoring

Intergrated veterinary anesthesia machine WMV680IIntergrated veterinary anesthesia machine WMV680I
Integrated animal-specific

bellow and absorber design

2 spare power sockets can be

connected to monitors, oxygen

concentrators or infusion pumps