Veterinary Anesthesia machine WMV-680Hplus
WMV-680Hplus Veterinary Anesthesia Machine is an very excellent machine.
It is portable and functional,which ensure it is a safe, stable and quality product.
lt is used in veterinary hospital, lab, farm and zoo etc.
PRODUCT DETAILS
● Gas Source:02,02&Air/N20(Option);
● Flow Meter: 2 tubes 02,02&Air(Option),O2&N20(Option);
● O2 Flush:35-75L/min;
● Selectatec Mounting Bar: Single;
● CO2 Circle Absorber:Rebreath;
● ACGO Port: Non-Rebreath;
● One Key Switch: Switch between Rebreath or Non-Rebreath;
● Top Handle:Move easily;
● Safe Pressure Valve:less than10kpa;
● O2 Lost Alarm:Sound Alarm(Option);
● Screen:10.1"TFT touch screen;
● Mode:VCV,PCV,SIMV-VC,SIMV-PC.PSV,Manual,SIMV-PRVC(Option);
● Electric PEEP;
● Battery Type:Li-ion,3 hours working;
● FiO2,EtCO2,EtAA(Option);
Anesthesia Ventilator: | |
Display:10.1" TFT, with touch screen; | |
Breath Mode:VCV,PCV,SIMV-VC,SIMV-PC,PSV,Manual/SPONT,Option:SIMV-PRVC; | |
Waveform:Pressure,Flow rate,Volume; | Loop:PV loop,PF loop.FV loop; |
O2 concentration Monitor:15%-100%(Option); | Electric PEEP: OFF, 3~30 cmH2O |
EtCo2,FiCO2(Option); | Battery Type:Li-ion,work time more than 3 hours; |
EtCO2,FiCO2,EtN2O, FiN2O, FiO2, EtO2, EtAA,FiAA,MAC(Option); |
Parameters setting range: | |
Tidal volume:50-1500ml,Option:10-1500ml; | Respiratory rate:1~100 bpm; |
Inspiratorytime:0.1~10.0s; | Respiratory rate:0~100 bpm; |
Percentage of inspiratory pause:0 to 60%; | Percentage of inspiratory pause:0 to 60%; |
Pressure Support:0~70 cmH20; | Pressure Control:5~70 cmH2O; |
Flow trigger:0.5~20L/min; | Pressure Trigger:0~20 cmH2O; |
PSV Insp Termination Level:5~80%; |
Monitored parameters: | |
Inspiratory tidal volume:0~3000 mL; | Expiratory tidal volume:0~3000 mL; |
Spontaneous minute ventilation:0~60L/min; | Minute ventilation:0~60 L/min; |
Respiratory ratio:4:1 to 1:10; | Spontaneous breathing frequency:0~100 bpm; |
Spontaneous breathing frequency:0~100 bpm; | Respiratory ratio:30:1 to 1:150; |
Peak airway pressure:0~100 cmH2O; | Mean airway pressure:0~100 cmH2O; |
Mean airway pressure:0~100 cmH2O; | Inspiratory plateau pressure:0~100 cmH2O; |
Inspiratory plateau pressure:0~100 cmH2O; | EtCO2,FiCO2(Option); |
EtCO2,FiCO2,EtN2O,FiN2O,FiO2, EtO2, EtAA, FiAA,MAC(Option); | |
Alarm settings: Tidal volume high/low alarm; Minute ventilation high/low alarm; Respiratory rate high/low alarm; Airway pressure high/low alarm; Continuous Positive Airway Pressure/Negative pressure alarm; Apnea alarm; Oxygen deficiency alarm; AC power failure alarm ,Low battery alarm,EtCO2,EtAA etc. |
Anesthesia Machine: | |
Gas Supply: | Gas Source: O2,or O2&Air(Option), or O2&N2O(Option); Gas Source Pressure Gauge: O2,or O2&Air(Option), or O2&N2O(Option); |
Pressure of Pipeline Inlet: | O2,280kPa~600kPa/41Psi~87Psi, less than 180L/min; N2O(Option),280kPa~600kPa/41Psi~87Psi,less than180L/min; Air(Option),280kPa~600kPa/41Psi~87Psi, less than 180L/min; Security Valve: release pressure less than 10 kpa; |
Security Valve: | release pressure less than 10 kpa; |
O2 Lost Alarm(Option): | Sound alarm, alimumun cylinder with whistle; |
N2O cut off valve protection(Option): | when O2 is lost, N2O will be cut off. |
Flow Meter: | |
2 tubes high precision flow meter,0~1L/min,1.1L/min~10L/min; or 0L/min~10L/min(O2&Air or O2&N2O); | |
Precision: | At 20 degree, atmospheric pressure is 101.3kPa, the precision of flow meter is level:2.5; |
O2&N2O Linkage Device(O2&N2O,Option): | make insure O2 concentration is not lower than 25%; |
O2 Flush: | 35L/min~75L/min; |
One Key Switch: | Switch between rebreath and Non-Rebreath; |
ACGO Port: | Non-Rebreath; |
Selectatec Mounting Bar: | single place used for vaporizer, it is easy to replace vaporizer; |
Anesthesia Vaporizer: | one of lsoflurane/Halothane/Sevoflurane |
Respiration System/CO2 Circle Absorber/Rebreath: | |
Soda Llme Chamber:800mL or 1600ml(Option); | Airway Pressure Gauge:-20-100cmH2O; |
Pop Off Vlave: with one key to close;APL valve(Option): 0.19~6kPa; | |
Dimension&Weight:Trolley Stand:55cm*56cm*153cm,50kg; | |
Standard Configuration: Anesthesia machine, one unit X60 Anesthesia vaporizer, one set adult disposable breath circuit, one set pediatric disposable breath circuit, 0.5,1.2,3L airbag, O2, or O2&N2O, or O2&Air gas source pipeline. |