Veterinary Medical Solution Supplier

Veterinary Anesthesia machine WMV-680Hplus

WMV-680Hplus Veterinary Anesthesia Machine is an very excellent machine.

It is portable and functional,which ensure it is a safe, stable and quality product.

lt is used in veterinary hospital, lab, farm and zoo etc.


Share:

PRODUCT DETAILS

● Gas Source:02,02&Air/N20(Option);

● Flow Meter: 2 tubes 02,02&Air(Option),O2&N20(Option);

● O2 Flush:35-75L/min;

● Selectatec Mounting Bar: Single;

● CO2 Circle Absorber:Rebreath;

● ACGO Port: Non-Rebreath;

● One Key Switch: Switch between Rebreath or Non-Rebreath;

● Top Handle:Move easily;

● Safe Pressure Valve:less than10kpa;

● O2 Lost Alarm:Sound Alarm(Option);

● Screen:10.1"TFT touch screen;

● Mode:VCV,PCV,SIMV-VC,SIMV-PC.PSV,Manual,SIMV-PRVC(Option);

● Electric PEEP;

● Battery Type:Li-ion,3 hours working;

● FiO2,EtCO2,EtAA(Option);

Anesthesia Ventilator:

Display:10.1" TFT, with touch screen;

Breath Mode:VCV,PCV,SIMV-VC,SIMV-PC,PSV,Manual/SPONT,Option:SIMV-PRVC;

Waveform:Pressure,Flow rate,Volume;

Loop:PV loop,PF loop.FV loop;

O2 concentration Monitor:15%-100%(Option);

Electric PEEP: OFF, 3~30 cmH2O

EtCo2,FiCO2(Option);

Battery Type:Li-ion,work time more than 3 hours;

EtCO2,FiCO2,EtN2O, FiN2O, FiO2, EtO2, EtAA,FiAA,MAC(Option);

Parameters setting range:

Tidal volume:50-1500ml,Option:10-1500ml;

Respiratory rate:1~100 bpm;

Inspiratorytime:0.1~10.0s;

Respiratory rate:0~100 bpm;

Percentage of inspiratory pause:0 to 60%;

Percentage of inspiratory pause:0 to 60%;

Pressure Support:0~70 cmH20;

Pressure Control:5~70 cmH2O;

Flow trigger:0.5~20L/min;

Pressure Trigger:0~20 cmH2O;

PSV Insp Termination Level:5~80%;

Monitored parameters:

Inspiratory tidal volume:0~3000 mL;

Expiratory tidal volume:0~3000 mL;

Spontaneous minute ventilation:0~60L/min;

Minute ventilation:0~60 L/min;

Respiratory ratio:4:1 to 1:10;

Spontaneous breathing frequency:0~100 bpm;

Spontaneous breathing frequency:0~100 bpm;

Respiratory ratio:30:1 to 1:150;

Peak airway pressure:0~100 cmH2O;

Mean airway pressure:0~100 cmH2O;

Mean airway pressure:0~100 cmH2O;

Inspiratory plateau pressure:0~100 cmH2O;

Inspiratory plateau pressure:0~100 cmH2O;

EtCO2,FiCO2(Option);

EtCO2,FiCO2,EtN2O,FiN2O,FiO2, EtO2, EtAA, FiAA,MAC(Option);

Alarm settings:

Tidal volume high/low alarm; Minute ventilation high/low alarm; Respiratory rate high/low alarm; Airway pressure high/low alarm; Continuous Positive Airway Pressure/Negative pressure alarm; Apnea alarm; Oxygen deficiency alarm; AC power failure alarm ,Low battery alarm,EtCO2,EtAA etc.

Anesthesia Machine:


Gas Supply:

Gas Source: O2,or O2&Air(Option), or O2&N2O(Option);

Gas Source Pressure Gauge: O2,or O2&Air(Option), or O2&N2O(Option);

Pressure of Pipeline Inlet:

O2,280kPa~600kPa/41Psi~87Psi, less than 180L/min;

N2O(Option),280kPa~600kPa/41Psi~87Psi,less than180L/min;

Air(Option),280kPa~600kPa/41Psi~87Psi, less than 180L/min;

Security Valve: release pressure less than 10 kpa;

Security Valve:

release pressure less than 10 kpa;

O2 Lost Alarm(Option):

Sound alarm, alimumun cylinder with whistle;

N2O cut off valve protection(Option):

when O2 is lost, N2O will be cut off.

Flow Meter:

2 tubes high precision flow meter,0~1L/min,1.1L/min~10L/min; or 0L/min~10L/min(O2&Air or O2&N2O);

Precision:

At 20 degree, atmospheric pressure is 101.3kPa, the precision of flow meter is level:2.5;

O2&N2O Linkage Device(O2&N2O,Option):

make insure O2 concentration is not lower than 25%;

O2 Flush:

35L/min~75L/min;

One Key Switch:

Switch between rebreath and Non-Rebreath;

ACGO Port:

Non-Rebreath;

Selectatec Mounting Bar:

single place used for vaporizer, it is easy to replace vaporizer;

Anesthesia Vaporizer:

one of lsoflurane/Halothane/Sevoflurane

Respiration System/CO2 Circle Absorber/Rebreath:

Soda Llme Chamber:800mL or 1600ml(Option);

Airway Pressure Gauge:-20-100cmH2O;

Pop Off Vlave: with one key to close;APL valve(Option): 0.19~6kPa;

Dimension&Weight:Trolley Stand:55cm*56cm*153cm,50kg;

Standard Configuration:

Anesthesia machine, one unit X60 Anesthesia vaporizer, one set adult disposable breath circuit, one set

pediatric disposable breath circuit, 0.5,1.2,3L airbag, O2, or O2&N2O, or O2&Air gas source pipeline.


SEND MESSAGE